EEPROM-analyse

Bekijk de EEPROM-parameters van een warmtepomp of vergelijk twee apparaten

Apparaten met dump 16
Registers met naam 291 / 512
Onbekende registers 221
Verschillen –
2d4049 Amber 120
Firmware
0.9.0
Programma
286
EEPROM
114 (201/146)
Uitgelezen
18 sep 2026 17:16

Registers

512 registers van dit apparaat

Register Naam Waarde
3000 EEPROM data length / CRC start byte (0x000) 255
3001 Cooling frequency F0 0
3002 Cooling frequency F1 20
3003 Cooling frequency F2 26
3004 Cooling frequency F3 30
3005 Cooling frequency F4 36
3006 Cooling frequency F5 43
3007 Cooling frequency F6 48
3008 Cooling frequency F7 55
3009 Cooling frequency F8 69
3010 Cooling frequency F9 74
3011 Cooling frequency F10 82
3012 Heating frequency F0 0
3013 Heating frequency F1 28
3014 Heating frequency F2 36
3015 Heating frequency F3 43
3016 Heating frequency F4 55
3017 Heating frequency F5 61
3018 Heating frequency F6 67
3019 Heating frequency F7 72
3020 Heating frequency F8 79
3021 Heating frequency F9 85
3022 Heating frequency F10 90
3023 Compressor start plateau 1 frequency (Hz) 55
3024 Compressor start plateau 2 frequency (Hz) 55
3025 4-way valve polarity (0=reverse/cool, 1=normal/heat) 0
3026 Onbekend 0
3027 Onbekend 0
3028 UART1 inverter protocol extended frame option 0
3029 EEV control mode (0=ext, 3=SH+cascade, 5=ambient band) 5
3030 Target superheat heating ambient < -15C (mode 5) 20
3031 Target superheat heating ambient -15 to -5C (mode 5) 20
3032 Target superheat heating ambient -5 to 5C (mode 5) 25
3033 Target superheat heating ambient 5 to 10C (mode 5) 30
3034 Target superheat heating ambient 10 to 30C (mode 5) 35
3035 Target superheat heating ambient >= 30C (mode 5) 30
3036 Target superheat offset water < 35C (mode 5) 5
3037 Target superheat offset water >= 55C (mode 5) 5
3038 EEV start correction at low water temp 11
3039 Onbekend 0
3040 Crankcase heater max on-time ambient >= -15C 3
3041 Crankcase heater max on-time ambient -20 to -15C 6
3042 Crankcase heater max on-time ambient -30 to -20C 12
3043 Crankcase heater max on-time ambient < -30C 18
3044 Crankcase heater min off-time before restart 2
3045 EEV start heating: water < 30C, ambient -15 to -10C 170
3046 EEV start heating: water < 30C, ambient < -20C 170
3047 EEV start heating: water 30-45C, ambient -15 to -10C 190
3048 EEV start heating: water 30-45C, ambient < -20C 190
3049 EEV start heating: water >= 45C, ambient -15 to -10C 195
3050 EEV start heating: water >= 45C, ambient < -20C 195
3051 Onbekend 0
3052 Onbekend 0
3053 Onbekend 0
3054 Onbekend 0
3055 Onbekend 0
3056 Onbekend 0
3057 Onbekend 0
3058 Onbekend 0
3059 Onbekend 0
3060 Onbekend 0
3061 Onbekend 0
3062 Onbekend 0
3063 Onbekend 0
3064 Onbekend 0
3065 Onbekend 0
3066 Onbekend 0
3067 Onbekend 0
3068 Onbekend 0
3069 Onbekend 0
3070 Onbekend 0
3071 Onbekend 0
3072 Onbekend 0
3073 Onbekend 0
3074 Onbekend 0
3075 Onbekend 0
3076 Onbekend 0
3077 Onbekend 0
3078 Onbekend 0
3079 Onbekend 0
3080 Oil return interval heating ambient 0-14C (min) 170
3081 Onbekend 0
3082 Onbekend 0
3083 Onbekend 0
3084 Onbekend 0
3085 Extra input / R290 leak detector timer (min, V2) 0
3086 Onbekend 0
3087 Onbekend 0
3088 Max compressor step heating subband 1 (V2) 0
3089 Max compressor step heating subband 2 (V2) 0
3090 Max compressor step heating subband 3 (V2) 0
3091 Onbekend 0
3092 Onbekend 0
3093 Onbekend 0
3094 Onbekend 0
3095 Onbekend 0
3096 Onbekend 0
3097 Onbekend 0
3098 Soft low pressure threshold (0.1 bar, V2) 0
3099 Soft low pressure timer (min, V2) 0
3100 Soft low pressure max compressor step (V2) 0
3101 Onbekend 0
3102 Onbekend 0
3103 Condensation temp limit heating 1 (V2) 0
3104 Condensation temp limit heating 2 (V2) 0
3105 Onbekend 0
3106 Onbekend 0
3107 Onbekend 0
3108 Onbekend 0
3109 Onbekend 0
3110 Onbekend 0
3111 Onbekend 0
3112 Onbekend 0
3113 Onbekend 0
3114 Onbekend 0
3115 Onbekend 0
3116 Onbekend 0
3117 Onbekend 0
3118 Onbekend 0
3119 Onbekend 0
3120 Onbekend 0
3121 Onbekend 0
3122 Onbekend 0
3123 Onbekend 0
3124 Onbekend 0
3125 Onbekend 0
3126 Onbekend 0
3127 Onbekend 0
3128 Onbekend 0
3129 Onbekend 0
3130 Onbekend 0
3131 Onbekend 0
3132 Onbekend 0
3133 Onbekend 0
3134 Onbekend 0
3135 Onbekend 0
3136 Onbekend 0
3137 Onbekend 0
3138 Onbekend 0
3139 Onbekend 0
3140 Onbekend 0
3141 Onbekend 0
3142 Onbekend 0
3143 Onbekend 0
3144 Onbekend 0
3145 Onbekend 0
3146 Onbekend 0
3147 Onbekend 0
3148 Onbekend 0
3149 Onbekend 0
3150 Onbekend 0
3151 Onbekend 0
3152 Onbekend 0
3153 Onbekend 0
3154 Onbekend 0
3155 Onbekend 0
3156 Onbekend 0
3157 Onbekend 0
3158 Onbekend 0
3159 Onbekend 0
3160 Onbekend 0
3161 Onbekend 0
3162 Onbekend 0
3163 Onbekend 0
3164 Onbekend 0
3165 Onbekend 0
3166 Onbekend 0
3167 Onbekend 0
3168 Onbekend 0
3169 Onbekend 0
3170 Onbekend 0
3171 Onbekend 0
3172 Onbekend 0
3173 Onbekend 0
3174 Onbekend 0
3175 Onbekend 0
3176 Onbekend 0
3177 Onbekend 0
3178 Onbekend 0
3179 Onbekend 0
3180 Onbekend 0
3181 Onbekend 0
3182 Onbekend 0
3183 Onbekend 0
3184 Onbekend 0
3185 Onbekend 0
3186 Onbekend 0
3187 Onbekend 0
3188 Onbekend 0
3189 Onbekend 0
3190 Onbekend 0
3191 Onbekend 0
3192 Onbekend 0
3193 Onbekend 0
3194 Onbekend 0
3195 Onbekend 0
3196 Onbekend 0
3197 Onbekend 0
3198 Onbekend 0
3199 Onbekend 0
3200 Onbekend 0
3201 Onbekend 0
3202 Onbekend 0
3203 Onbekend 0
3204 Onbekend 0
3205 Onbekend 0
3206 Onbekend 0
3207 Onbekend 0
3208 Onbekend 0
3209 Onbekend 0
3210 Onbekend 0
3211 Onbekend 0
3212 Onbekend 0
3213 Onbekend 0
3214 Onbekend 0
3215 Onbekend 0
3216 Onbekend 0
3217 Onbekend 0
3218 Onbekend 0
3219 Onbekend 0
3220 Onbekend 0
3221 Onbekend 0
3222 Onbekend 0
3223 Onbekend 0
3224 Onbekend 0
3225 Onbekend 0
3226 Onbekend 0
3227 Onbekend 0
3228 Onbekend 0
3229 Onbekend 0
3230 EEV2 (injection) control mode (0=ext, 1=auto) 1
3231 EEV opening during defrost 135
3232 EEV1 initial opening after homing 135
3233 Onbekend 0
3234 EEV opening during 4-way valve switching 0
3235 Baud Rate UART3 4
3236 Parity Check UART3 1
3237 Working mode of bottom plate heater 2
3238 Ambient temperature to start bottom plate heater 34
3239 Stop hysteresis of bottom plate heater 3
3240 Ambient temperature to start crankcase heater 33
3241 Crankcase heater restart temp / V1 stop hysteresis 33
3242 Onbekend 0
3243 Onbekend 0
3244 Onbekend 0
3245 High pressure sensor type (0=none, 1=50bar, 2=46bar) 1
3246 Low pressure sensor enable 1
3247 High pressure protection shutdown value (bar) 31
3248 Low pressure protection shutdown value (0.1 bar) 4
3249 Fan control mode (0=external, 1=auto) 1
3250 Fan control method (0=speed table, !=0=relays) 0
3251 Fan speed heating step 1 / defrost high pressure 40
3252 Fan speed heating step 2 44
3253 Fan speed heating step 3 48
3254 AC current shutdown threshold cooling 16
3255 AC current speed-down threshold cooling 15
3256 AC current release threshold cooling 14
3257 AC current shutdown threshold heating 16
3258 AC current speed-down threshold heating 15
3259 AC current release threshold heating 14
3260 Discharge temp shutdown threshold 140
3261 Discharge temp fast speed-down threshold 135
3262 Discharge temp speed-down / EEV open threshold 130
3263 Discharge temp protection release threshold 125
3264 Outdoor coil temp shutdown threshold cooling 92
3265 Outdoor coil temp speed-down threshold cooling 89
3266 Outdoor coil temp hold threshold cooling 87
3267 Outdoor coil temp release threshold cooling 82
3268 High pressure speed-down threshold (bar) 30
3269 High pressure frequency hold threshold (bar) 28
3270 High pressure protection release threshold (bar) 26
3271 Defrost algorithm 4: defrost interval (min) 45
3272 Onbekend 12
3273 Cooling frost protection: strong speed-down temp 32
3274 Cooling frost protection: 45Hz limit temp 33
3275 Defrost control mode (0=master, 1=auto ODU) 1
3276 Defrost algorithm mode 4
3277 Enter defrost outdoor coil temp 1 (ambient >= 3C) 27
3278 Exit defrost outdoor coil temperature 47
3279 Maximum defrosting time (min) 8
3280 Defrost 4-way valve switching frequency (Hz) 36
3281 Defrost running frequency (Hz) 61
3282 Frequency limitation control for ambient outdoor temp 1
3283 Max compressor step cooling ambient < 0C 0
3284 Max compressor step cooling ambient 0-12C 2
3285 Max compressor step cooling ambient 12-18C 3
3286 Max compressor step cooling ambient 18-24C 6
3287 Max compressor step cooling ambient 24-30C 10
3288 Max compressor step cooling ambient 30-41C 10
3289 Max compressor step cooling ambient 41-45C 7
3290 Max compressor step cooling ambient 45-51C 4
3291 Max compressor step cooling ambient 51-65C 1
3292 Max compressor step cooling ambient >= 65C 0
3293 Max compressor step heating below min ambient 0
3294 Max compressor step heating min ambient to 12C 10
3295 Max compressor step heating ambient 12-20C 8
3296 Max compressor step heating ambient 20-24C 5
3297 Max compressor step heating ambient 24-28C 3
3298 Max compressor step heating ambient 28-46C 2
3299 Max compressor step heating ambient >= 46C 0
3300 Onbekend 0
3301 Inverter config byte 2 (low byte of 2114) 0
3302 Fan speed heating step 4 52
3303 Fan speed heating step 5 53
3304 Fan speed heating step 6 56
3305 Fan speed heating step 7 68
3306 Fan speed heating step 8 72
3307 Fan speed heating step 9 (Max fan setpoint) 78
3308 Defrost algo 4 min runtime (min) / Doc: Low noise switch 5
3309 Low noise mode max fan speed 62
3310 Fan configuration (0=dual fan, !=0=single fan) 1
3311 EEPROM parameter set version 114
3312 Defrost algorithm 3: cold mode ambient threshold 10
3313 Defrost algorithm 4: max runtime before defrost (min) 180
3314 Defrost algorithm 4: ambient threshold for exit criteria 5
3315 Defrost algorithm 4: min interval for criterion (min) 25
3316 Defrost algorithm 3: change threshold 40
3317 Setting of the model (main PCB) address (unused in 1.30) 2
3318 Onbekend 0
3319 Defrost fan turn-on high pressure threshold (bar) 29
3320 Oil return running frequency (Hz) 61
3321 Fan speed cooling step 1 (Fan low setpoint 1) 62
3322 Fan speed cooling step 2 (Fan low setpoint 2) 62
3323 Fan speed cooling step 3 (Fan low setpoint 3) 62
3324 Fan speed cooling step 4 (Fan mid setpoint 1) 68
3325 Fan speed cooling step 5 (Fan mid setpoint 2) 68
3326 Fan speed cooling step 6 (Fan mid setpoint 3) 68
3327 Fan speed cooling step 7 (Fan setpoint high 1) 72
3328 Fan speed cooling step 8 (Fan setpoint high 2) 72
3329 Fan speed cooling step 9 (Fan setpoint high 3) 72
3330 Grid undervoltage shutdown threshold (V) 140
3331 Grid voltage band 3 threshold (V) 156
3332 Grid voltage band 2 threshold (V) 170
3333 Grid voltage band 1 threshold (V) 188
3334 Max compressor step in voltage band 3 2
3335 Max compressor step in voltage band 2 5
3336 Max compressor step in voltage band 1 6
3337 Enter defrost outdoor coil temp 2 (ambient -3 to 3C) 27
3338 Enter defrost outdoor coil temp 3 (ambient -10 to -3C) 25
3339 Enter defrost outdoor coil temp 4 (ambient < -10C) 18
3340 Defrost exit confirmation time (s) 10
3341 Immediate defrost exit outdoor coil temp 55
3342 Fixed 45 min defrost interval at ambient -3 to 3C enable 1
3343 Compressor current speed-down threshold 25
3344 Compressor current release threshold 22
3345 Inverter word 11 speed-down threshold 147
3346 Inverter word 11 release threshold 140
3347 Oil return timer frequency threshold / ramp frequency (Hz) 45
3348 Oil return interval cooling & heating outside 0-14C (min) 120
3349 EEV opening during oil return 150
3350 Onbekend 0
3351 Onbekend 0
3352 Onbekend 0
3353 Onbekend 0
3354 Onbekend 0
3355 Onbekend 0
3356 Model/capacity identity code (shown in 11006) 0
3357 Baud Rate UART1 2
3358 Parity Check UART1 0
3359 EEV standby position band 1 (ambient >= 30C) 50
3360 EEV standby position band 2 (ambient 10 to 30C) 100
3361 EEV standby position band 3 (ambient -5 to 10C) 135
3362 EEV standby position band 4 (ambient -15 to -5C) 175
3363 EEV standby position band 5 (ambient < -15C) 200
3364 EEV start heating: water < 30C, ambient >= 30C 105
3365 EEV start heating: water < 30C, ambient 10-30C 145
3366 EEV start heating: water < 30C, ambient 5-10C 155
3367 EEV start heating: water < 30C, ambient -5 to 5C 170
3368 EEV start heating: water < 30C, ambient -10 to -5C 170
3369 EEV start heating: water < 30C, ambient -20 to -15C 170
3370 EEV start heating: water 30-45C, ambient >= 30C 100
3371 EEV start heating: water 30-45C, ambient 10-30C 125
3372 EEV start heating: water 30-45C, ambient 5-10C 155
3373 EEV start heating: water 30-45C, ambient -5 to 5C 160
3374 EEV start heating: water 30-45C, ambient -10 to -5C 185
3375 EEV start heating: water 30-45C, ambient -20 to -15C 190
3376 EEV start heating: water >= 45C, ambient >= 30C 125
3377 EEV start heating: water >= 45C, ambient 10-30C 150
3378 EEV start heating: water >= 45C, ambient 5-10C 160
3379 EEV start heating: water >= 45C, ambient -5 to 5C 165
3380 EEV start heating: water >= 45C, ambient -10 to -5C 190
3381 EEV start heating: water >= 45C, ambient -20 to -15C 195
3382 EEV start cooling: water >= 18C, ambient >= 30C 10
3383 EEV start cooling: water >= 18C, ambient 20-30C 10
3384 EEV start cooling: water >= 18C, ambient < 20C 10
3385 EEV start cooling: water 12-18C, ambient >= 30C 10
3386 EEV start cooling: water 12-18C, ambient 20-30C 10
3387 EEV start cooling: water 12-18C, ambient < 20C 10
3388 EEV start cooling: water < 12C, ambient >= 30C 10
3389 EEV start cooling: water < 12C, ambient 20-30C 10
3390 EEV start cooling: water < 12C, ambient < 20C 10
3391 Discharge superheat upper limit for 0K suction target 38
3392 Max suction superheat target in discharge cascade 11
3393 Suction superheat interpolation base in cascade 27
3394 Base target suction superheat (K) 10
3395 Extra target superheat after start (360s decay) 10
3396 Extra target superheat after defrost (480s decay) 10
3397 Fallback suction temp offset on sensor fault 5
3398 Low water temp threshold for EEV start correction 45
3399 Onbekend 0
3400 Onbekend 0
3401 Onbekend 0
3402 Onbekend 0
3403 Onbekend 0
3404 Onbekend 0
3405 Onbekend 0
3406 Onbekend 0
3407 Onbekend 0
3408 Onbekend 0
3409 Onbekend 0
3410 Onbekend 0
3411 Onbekend 0
3412 Onbekend 0
3413 Onbekend 0
3414 Emergency pump duty cycle on comm loss (%) 0
3415 Defrost algo 4: evap temp diff ambient 0 to 9C 17
3416 Defrost algo 4: evap temp diff ambient -5 to 0C 18
3417 Defrost algo 4: evap temp diff ambient -10 to -5C 18
3418 Defrost algo 4: evap temp diff ambient -15 to -10C 19
3419 Defrost algo 4: evap temp diff ambient -20 to -15C 20
3420 Defrost algo 4: evap temp diff ambient -23 to -20C 22
3421 Defrost algo 4: evap temp diff ambient < -23C 24
3422 Defrost algo 4: evap temp diff ambient < 7C after timer 14
3423 Defrost algo 4: exit coil temp at low ambient 55
3424 Defrost fan drip time (s) 0
3425 Onbekend 0
3426 Onbekend 0
3427 Defrost algo 4: exit confirmation time 1 (s) 3
3428 Defrost algo 4: exit confirmation time 2 (s) 3
3429 EEV feedforward coeff A high byte 0
3430 EEV feedforward coeff A low byte 190
3431 EEV feedforward term B high byte 3
3432 EEV feedforward term B low byte 198
3433 EEV feedforward duration after freq change (s) 30
3434 Temporary frequency ceiling after mode change/defrost (Hz) 45
3435 Temporary frequency ceiling duration (s) 30
3436 Onbekend 0
3437 Oil return duration at target frequency (min) 2
3438 Oil return maximum duration (min) 3
3439 Oil return pre-ramp duration at 45Hz (s) 30
3440 Oil return post-ramp duration at 45Hz (s) 30
3441 Onbekend 0
3442 Condensation temp limit heating 3 (V2) 0
3443 Condensation temp limit heating 4 (V2) 0
3444 Onbekend 0
3445 Onbekend 0
3446 Onbekend 0
3447 Onbekend 0
3448 Onbekend 0
3449 Onbekend 0
3450 EEV feedforward coeff C high byte 0
3451 EEV feedforward coeff C low byte 169
3452 Onbekend 0
3453 Onbekend 0
3454 Onbekend 0
3455 Onbekend 0
3456 Min. flow rate (unused by firmware) 0
3457 Extra input / R290 leak sensor enable 0
3458 L1, L2, L3 & 4-way valve relay control by master (2010) 0
3459 Water flow sensor type (0=none, 1=Sika, 2=Huba, 3=10L/min/V) 0
3460 Second expansion valve (EEV2 injection) enable 0
3461 EEV2 control interval 15
3462 EEV2 maximum opening 44
3463 EEV2 minimum opening 30
3464 EEV2 active ambient temperature threshold 12
3465 EEV2 minimum compressor frequency (Hz) 45
3466 EEV2 start opening (x10) 42
3467 EEV2 active control discharge temp threshold 97
3468 EEV2 turn-on discharge temp threshold 45
3469 Onbekend 80
3470 EEV2 gain on discharge temp error 2
3471 EEV2 gain on discharge temp change 1
3472 EEV2 target setting ambient < -20C 31
3473 EEV2 target setting ambient -20 to 0C 31
3474 EEV2 target setting ambient 0 to 20C 31
3475 EEV2 target setting ambient 20 to 40C 31
3476 EEV2 target setting ambient >= 40C 31
3477 Target discharge superheat base (K) 15
3478 Target discharge superheat slope per step (0.1 K) 5
3479 EEV PID control interval (s) 15
3480 EEV maximum opening in auto mode (x2 steps) 215
3481 EEV minimum opening in auto mode (x2 steps) 10
3482 EEV max step size per interval 15
3483 EEV PID proportional gain (P) 6
3484 EEV PID integral gain (I) 5
3485 EEV PID derivative gain (D) 4
3486 Onbekend 0
3487 Onbekend 0
3488 Onbekend 0
3489 Onbekend 0
3490 Onbekend 0
3491 Onbekend 0
3492 Inverter communication protocol type 2
3493 Inverter protocol variant (0=voltage limit active) 0
3494 Water temperature sensors on ODU enable 0
3495 Water flow correction value (unused by firmware) 0
3496 Inverter config byte 1 (high byte of 2114) 0
3497 DC water pump control mode 0
3498 Refrigerant type (0=R32/R410A, 1=R290) 1
3499 Heating min ambient temperature base (offset 30) 5
3500 Heating min ambient temperature reduction 0
3501 Heating min ambient temperature extra hysteresis 4
3502 Water pump high speed power (unused by firmware) 0
3503 Water pump medium speed power (unused by firmware) 0
3504 Water pump low speed power (unused by firmware) 0
3505 DC fan high speed power (unused by firmware) 0
3506 DC fan medium speed power (unused by firmware) 0
3507 DC fan low speed power (unused by firmware) 0
3508 Heating outlet temp diff correction (unused by firmware) 0
3509 Cooling outlet temp diff correction (unused by firmware) 0
3510 Checksum low byte (CRC-16/Modbus) 146
3511 Checksum high byte (CRC-16/Modbus) 201
512 registers getoond